High-Temperature Bottom Loading Furnaces up to 1700 ˇăC
Quantity
View old post here.
The motor-driven lifting table significantly simplifies the charging of the high-temperature furnaces LHT/LB. The heating all around the cylindrical furnace chamber provides for an opitimal temperature uniformity. For the tabletop models LHT 01/17 LB and LHT 02/17 LB the charge can be placed in charge saggars made of technical ceramics. Up to three charge saggars can be stacked on top of each other resulting in a high productivity. Due to its volume the high-temperature furnace LHT 16/17 LB can also be used for applications in production.
- Tmax 1650 °C, 1700 °C (LHT 16/17 LB)
- High-quality heating elements made of molybdenum disilicide offer best possible protection against chemical interaction between charge and heating elements
- Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
- Outstanding temperature uniformity due to all-round furnace chamber heating
- Furnace chamber with a volume of 1, 2 or 16 liters, table with large floor space
- Precise, motorized toothed belt drive of the table with button operation
- Appealing, dual shell stainless steel housing
- Exhaust air vent in the roof
- Type S thermocouple
- Defined application within the constraints of the operating instructions
- NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Additional equipment
- Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
- Stackable saggars for loading in up to two or three levels, depending on model
- Protective gas connection to purge with non-flammable protective or reaction gases
- Manual or automatic gas supply system
- Adjustable air inlet through the floor
- Process control and documentation via VCD software package for monitoring, documentation and control
Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions1 in mm | Connected | Electrical | Weight | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
°C | w | d | h | in l | W | D | H | load kW | connection* | in kg | |
LHT 01/17 LB | 1650 | 145 | 180 | 100 | 1 | 350 | 590 | 680 | 2.2 | 1-phase | 40 |
LHT 02/17 LB | 1650 | 185 | 180 | 185 | 2 | 390 | 590 | 765 | 3.4 | 1-phase | 50 |
LHT 16/17 LB | 1700 | Ø 260 | 260 | 16 | 650 | 1250 | 1980 | 12.0 | 3-phase | 410 |