Product Features
- DC/AC 0.01A Resolution
- AC/DC 0.01A~200A
- 23mm Jaw Diameter
- One Touch Zero
- Temperature and Capacitance
- Auto Range V ¡¢Hz¡¢¡æ¡¢
- 3 3/4 Digits (4000 Counts)
DC Current |
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
40A
|
10mA
|
+/-1.5%+/-2dgts
|
DC400A |
0-150A
|
0.1A
|
+/-1.5%+/-2dgts
|
|
150-200A
|
0.1A
|
+/-1.5.5%+/-3dgts
|
AC Voltage (Autorange , Input Impedance 5M W ) |
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
4V
|
0.001V
|
+/-1.5%+/-5dgts
|
AC 800V
|
40V
|
0.01V
|
+/-1.5%+/-5dgts
|
|
400V
|
0.1V
|
+/-1.5%+/-5dgts
|
|
600V
|
1V
|
+/-1.5%+/-5dgts
|
Frequency (Hz, Autorange & Sensitivity selected by RANGE button) |
Range
|
Resolution
|
Accuracy
|
Sensitivity
|
Overload Protection
|
100-1000kHz
|
0.01-100Hz
|
+/-0.5%+/-2dgts
|
10 mV /0.1V/1V
|
AC600V
|
Resistance( W )&Audible Continuity (Open Circuit Voltage 0.5V): |
Range
|
Resolution
|
Accuracy
|
Beeper
|
Overload Protection
|
40-400 W
|
0.1 W
|
+/-1.0%+/-5dgts
|
<=40 W (approx)
|
AC600V
|
Resistance( W )(Autorange & Manual , Open Voltage<=0.5V) |
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
400 W
|
0.1 W
|
+/-1.5%+/-3dgts
|
600VAC
|
4K W
|
1 W
|
+/-1.5%+/-3dgts
|
|
40K W
|
10 W
|
+/-1.5%+/-3dgts
|
|
400K W
|
100 W
|
+/-1.5%+/-3dgts
|
|
4M W
|
1K W
|
+/-1.5%+/-3dgts
|
|
40M W
|
10K W
|
+/-1.5%+/-3dgts
|
Capacitance (Autorange & Manual) |
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
4nF
|
1pF
|
+/-5.0%+/-0.2 nF
|
AC600V
|
40nF
|
10pF
|
+/-5.0%+/-0.2 nF
|
|
400nF
|
0.1nF
|
+/-3.0%+/-0.2 nF
|
|
4uF
|
1nF
|
+/-3.0%+/-0.2 uF
|
|
40uF
|
10nF
|
+/-3.0%+/-0.2 uF
|
TEMP K TYPE ¡æ (Autorange & Manual, ¨H optional): |
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
-40 - 0 ¡æ
|
0.1 ¡æ
|
+/-2.0 %+/-5 ¡æ
|
AC600V
|
0- 400 ¡æ
|
0.1 ¡æ
|
+/-0.5 %+/-1 ¡æ
|
|
400- 1200 ¡æ
|
1 ¡æ
|
+/-0.8 %+/-1 ¡æ
|
600V
|
General Specification |
Conductor Size | 23mm Diameter |
Battery | 1.5V AA UM3 Battery x 2 |
Display | 3 3/4Diguts(4000Counts) |
Range Selection | Auto and Manual |
Power Consumption | 10mA (Approx) |
Sampling Time | 2Time/sec (Digital) 20Time/sec (Bar graph) |
Operating Temperature | 0 ¡æ ~ 50 ¡æ ( 32 ¨H ~122 ¨H ) |
Operating Humidity | LESS than 80% RH |
Dimension |
7.2'(L) x 2.5'(W) x 1.4'(H) 183mm(L) x 63.6mm(W) x 35.6mm(H) |
Weight | 190g. (Batteries Included) |
Accessories |
Adaptor (for K-type Thermocouple and Capacitor) x 1 User Manual x 1 5V Battery x 2 K-type Thermocouple x 1 Carrying Bag x 1 |