Fungilab - VISCOLEAD SERIES ONE
Quantity
Measuring of advanced viscosity. Easy to use. 2 years of garantee
Main Features
SCREEN DATA | |
---|---|
Selected speed | rpm |
Selected spindle | SP |
Viscosity reading | cP (mPa·s) |
Percentatge of full scale | % |
Sampling temperature | ºC or ºF |
VISCOSITY READING | |
---|---|
Dynamic viscosity | cP or mPa·s |
Units Converter | from SI to CGS |
OTHER MAIN FEATURES |
---|
AUTO-TEST with visual and resonant alarm |
AUTO-RANGE function |
User calibration viscosity enabled |
10 language options |
Spindles
AISI 316 Stainless steel spindle, easily to identify according to its letter and number, in terms of the range of viscosity. Our units fulfills the next standards: These are the standards our units follow: BS: 6075, 5350- BS: 6075, 5350
- ISO:2555,1652
- ASTM: 115, 789, 1076, 1084, 1286, 1417, 1439, 1638, 1824, 2196, 2336, 2364, 2393, 2556, 2669, 2849, 2983, 2994, 3232, 3236, 3716
Standard delivery
-
The equipement is supplied complete with standard spindles
- 4 spindles for L model
- 6 spindles for R and H models
- Viscometer stand
- Spindle protector
- Carring case
TECHNICAL SPECIFICATIONS
- Precision: +/- 1% full scale of range
- Resolution: For a minus viscosity of 10.000 cP : 0.1 cP For a major viscosity of 10.000 cP : 1 cP With the low viscosity adapter (LCP-LCP/B) : 0.01cP
- Repeatability: 0.2%
- Supplied at 110-240VAC, 50/60 Hz.
ACCESSORIES
- APM : Small Sample Adapter with circulation jacket (without TL or TR spindles) Sample volume (6.7 - 13 ml.) Compatible with Brookfield viscometers
- APM/B : Small Sample Adapter without circulation jacket (without TL or TR spindles) Sample volume (6.7 - 13 ml.) Compatible with Brookfield viscometers
- LCP : Low Viscosity Adapter with circulation jacket (with spindle) Sample volume (16 ml.) Compatible with Brookfield viscometers
- LCP/B : Low Viscosity Adapter without circulation jacket (with spindle) Sample volume (16 ml.) Compatible with Brookfield viscometers
- HELDAL : Helix Drive Unit Accessory for measuring non-flowing substances viscosity (with spindles)
- THERMOSPHERE : Temperature control unit up to 300 ºC
CODE | MODEL | MEASURING RANGE (CP) | SPEED (R.P.M) | NUMBER OF SPEEDS |
---|---|---|---|---|
VL100003 | ONE L | *1 - 2.000.000 | 0.3 - 100 | 18 |
VL100002 | ONE R | 100 - 13.000.000 | 0.3 - 100 | 18 |
VL100001 | ONE H | 200 - 106.000.000 | 0.3 - 100 | 18 |
PPRFast spindle switch (push plug and release)
CODE | MODEL | MEASURING RANGE (CP) | SPEED (R.P.M) | NUMBER OF SPEEDS |
---|---|---|---|---|
VL101003 | ONE L + PPR | *1 - 2.000.000 | 0.3 - 100 | 18 |
VL101002 | ONE R + PPR | 100 - 13.000.000 | 0.3 - 100 | 18 |
VL101001 | ONE H + PPR | 200 - 106.000.000 | 0.3 - 100 | 18 |
Ranges
- (L) Low viscosity model
- (M) Medium viscosity model
- (H) High viscosity model