Fungilab - MASTER SERIES SMART
Smart Series
Essential in investigation and quality control Laboratories.
SCREEN DATA |
Selected speed |
rpm |
Selected spindle |
SP |
Viscosity reading |
cP (mPa·s) or cSt |
Percentatge of full scale |
% |
Sample temperature |
ºC or ºF |
Shear Rate (with coaxial spindles) |
SR (s-1) |
Shear Stress (with coaxial spindles) |
SS (N/m2) |
Density (introduced by the user) |
g/cm3 |
VISCOSITY READING |
Dynamic viscosity |
cP or mPa·s |
Kinematic viscosity |
cSt |
Units Converter |
from SI to CGS |
PROGRAM FEATURES |
Time to torque: Ending of the test upon reaching a programmed torque |
Time to stop: Ending of the test upon reaching a programmed time |
10 working memories |
OTHER MAIN FEATURES |
AUTO-TEST with visual and resonant alarm |
AUTO-RANGE function |
Temperature Reading through PT100 probe |
User-enabled viscosity and temperature calibration |
6 language options |
Port: USB |
Datalogger: Posibility to tranfer data to a pendrive into Excel format |
6 key Touch Keyboard |
Spindles
AISI 316 Stainless steel spindle, easily to identify according to its letter and number, in terms of the range of viscosity. Our units fulfills the next standards: These are the standards our units follow: BS: 6075, 5350
-
BS: 6075, 5350
-
ISO:2555,1652
-
ASTM: 115, 789, 1076, 1084, 1286, 1417, 1439, 1638, 1824, 2196, 2336, 2364, 2393, 2556, 2669, 2849, 2983, 2994, 3232, 3236, 3716
Standard delivery
-
The equipement is supplied complete with standard spindles
-
4 spindles for L model
-
6 spindles for R and H models
-
Viscometer stand
-
Spindle protector
-
Temperature probe PT100
-
Carring case
TECHNICAL SPECIFICATIONS
-
Precision: +/- 1% full scale of range
-
Resolution: For a minus viscosity of 100 cP : 0.01 cP For a major viscosity of 1000 cP : 0.1 cP For a major viscosity of 5000 cP : 1.0 cP For a major viscosity of 10.000 cP : 5.0 cP For a major viscosity of 25.000 cP : 10.0 cP For a major viscosity of 50.000 cP : 25.0 cP For a major viscosity of 100.000 cP : 100.0 cP For a major viscosity of 1.000.000 cP : 1.000.0 cP
-
Repeatability: 0.2%
-
Temperature probe features: Temperature limits: -40ºC to 300ºC -40ºF to 572ºF Resolution: 0.1ºC / -17.722 ºF Precision: +/- 0.2ºC / +/- 17.666 ºF Type of probe: PT100
-
Supplied at 110-240VAC, 50/60 Hz.
-
Software: Fungilab Data Boss (optional): The Fungilab Data Boss software complies the FDA 21CFR PART 11 regulation
ACCESSORIES
-
APM : Small Sample Adapter with circulation jacket (without TL or TR spindles) Sample volume (6.7 - 13 ml.) Compatible with Brookfield viscometers
-
APM/B : Small Sample Adapter without circulation jacket (without TL or TR spindles) Sample volume (6.7 - 13 ml.) Compatible with Brookfield viscometers
-
LCP : Low Viscosity Adapter with circulation jacket (with spindle) Sample volume (16 ml.) Compatible with Brookfield viscometers
-
LCP/B : Low Viscosity Adapter without circulation jacket (with spindle) Sample volume (16 ml.) Compatible with Brookfield viscometers
-
HELDAL : Helix Drive Unit Accessory for measuring non-flowing substances viscosity (with spindles)
-
THERMOSPHERE : Temperature control unit up to 300 ºC
CODE |
MODEL |
MEASURING RANGE (CP) |
SPEED (R.P.M) |
NUMBER OF SPEEDS |
V210003 |
SMART L |
*1 - 6.000.000 |
0.01 - 200 |
54 |
V210002 |
SMART R |
25 - 40.000.000 |
0.01 - 200 |
54 |
V210001 |
SMART H |
200 - 320.000.000 |
0.01 - 200 |
54 |
The viscosity range of the equipment is referenced between 0.01 and 100 rpm.
PPRFast spindle switch (push plug and release)
CODE |
MODEL |
MEASURING RANGE (CP) |
SPEED (R.P.M) |
NUMBER OF SPEEDS |
V211003 |
SMART L + PPR |
*1 - 6.000.000 |
0.01 - 200 |
54 |
V211002 |
SMART R + PPR |
25 - 40.000.000 |
0.01 - 200 |
54 |
V211001 |
SMART H + PPR |
200 - 320.000.000 |
0.01 - 200 |
54 |
The viscosity range of the equipment is referenced between 0.01 and 100 rpm.
Ranges
-
(L) Low viscosity model
-
(M) Medium viscosity model
-
(H) High viscosity model
Low viscosity:The minimum viscosity when using a 'L' range with standard spindles is 10cP. (*) For measurements <10cP, its recommended to use in conjunction with the low viscosity adaptor (LCP or LCP/B)