TIME - Concrete Thickness Gauge TC300
Quantity
Overview
TC300 is used for measuring the thickness of nonmetallic plate indirectly, especially for concrete slab. This gauge is to measure the concrete slab thickness mainly by using distribution characteristics of electromagnetic field and possesses function of thickness measurement, data analysis, data storage & output etc. It is a kind of intelligent thickness measuring instrument that is portable, convenient and accurate.
Features
¡ñ Measure the thickness of concrete, rock, glass and other nonmetallic plates.
¡ñ Sound alarm, signal strength bar are used to improve measuring accuracy.
¡ñ Direct digital read out of the thickness value avoid the inaccuracy of manual comparison.
¡ñ Test data create and data logging
¡ñ RS232 and USB interface to PC.
¡ñ Real time analysis of the tested data.
Standard Delivery
Main unit
|
1
|
Shoulder strap
|
1
|
Transmitting Transducer
|
1
|
AA battery (LR6)
|
6
|
Receiving Transducer
|
1
|
AAA battery (LR03)
|
6
|
Supporting bar
|
5
|
Key
|
2
|
Interphone
|
2
|
TIME certificate
|
1
|
Signal cable
|
1
|
Warranty card
|
1
|
Charger
|
1
|
Instruction manual
|
1
|
Technical Specifications
Measuring range
|
40-820mm
|
Accuracy
|
±1mm[When thickness = (40-600mm)]
|
±2mm[When thickness = (601-820mm)]
|
|
Memory
|
32000 test data and 4000 components
|
Power
|
AA batteries (LR6) x 6
|
Display
|
Large graphic display
|
Operating temperature
|
-10¡æ~40¡æ
|
Humidity
|
<90%
|
Dimension (mm)
|
210x153x90
|
Weight (g)
|
880
|